Go Direct ORP Electrode, Temperature range: 0-60 deg C, Dimension: 12 mm OD, Impedance: Approx 20 kOhm at 25 deg C, Redox potential range: -450 to +1100 mV, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, ORP element: 99% pure platinum band sealed on a glass stem
Go Direct* Constant Current System, is a DC power source with a built-in current probe designed for use in electrochemistry experiments, Specifications, Range: 0 to 0.6 A, Supply voltage: 5 VDC, Connections: Wireless Bluetooth, Wired USB
Go Direct* Conductivity Probe, determines the ionic content of an aqueous solution by measuring its electrical conductivity, Range: 0 to 20,000 uS/cm, Temperature compensation: Automatic from 5 to 35 deg C, can be turned off, Temperature range: 0 to 80 deg C
Go Direct* Light and Color Sensor, is a powerful and versatile light sensor that measures light in the visible to ultraviolet electromagnetic spectrum, light intensity in the visible range, UVA, and UVB portions of the electromagnetic spectrum
Go Direct* Electrode Amplifier, is a mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes, Specifications: Units: pH or mV, Input range (mV): +/-1000 mV, Input range: 0 to 14 pH, Connections: Wireless Bluetooth, Wired: USB
Go Direct* Voltage Probe, combines a wide input voltage range and high precision, Specifications: Input voltage range: +/-15.0 V, Maximum voltage on any input: +/-15 V, Typical resolution: 0.5 mV, Power: Internal rechargeable battery, Wireless: Bluetooth, Wired: USB
Go Direct* Force and Acceleration Sensor, couples a 3-axis accelerometer with a stable and accurate force sensor that measures forces as small as +/- 0.1 N and up to +/- 50 N, Acceleration: 3 axis, +/- 16 g, Gyroscope: 3 axis, 2000 deg /s
Go Direct* Acceleration Sensor, Low acceleration: +/-157 m/s2, High acceleration: +/-1,960 m/s2, Altimeter: -1,800 m to 10,000 m, Angle: +/-180 deg, with Wireless: Bluetooth Connections, Wired: USB Connection, Slip it into your pocket and pirouette or ride a half-pipe
Go Direct Respiration Belt, Range: 0-50 N, Resolution: 0.01 N, Response time: 50 ms, Maximum chest circumference: 140 cm, with Wireless: Bluetooth Connections, Wired: USB Connection, Measure steps and step rate during a study with the built-in pedometer
Go Wireless* Exercise Heart Rate, Recommended for College, High School, and Middle School Science, excellent hands-free option for continuously monitoring heart rate before, during, and after exercise or while a person is stationary
Go Direct* 3-Axis Magnetic Field Sensor, allows you to determine the magnitude and direction of the magnetic field at any point in space, Measurement range: +/-5 Mt, Operating temperature: -40 deg C to 85 deg C, Dimensions: 19x12.2x0.7 cm, Factory-calibrated
Go Direct* Temperature Probe, is a rugged, general-purpose temperature sensor that students can use to monitor temperature, Temperature range: -40 to 125 deg C, Handle temperature range: -10 to 45 deg C, Resolution: 0.07 deg C, Connections: Wireless Bluetooth, Wired USB
Go Direct* Colorimeter, measures absorbance or transmittance of a liquid sample, Specifications: Range: 0 to 3 (absorbance), Useful range: 0.05 to 1.0 (absorbance), 90% to 10% transmittance (%T), Wavelengths: 430 nm, 470 nm, 565 nm, 635 nm, Connections: Bluetooth, USB
Go Direct* Surface Temperature Sensor, Range: -25 to 125 deg C, Accuracy: +/-0.5 degC, Response time (from 25 C to 100 deg C in water): 5 seconds, Dimension: 6.8x2.25x1.3cm, Cable length: 1 m, with Wireless: Bluetooth, Wired: USB Connection
Digital Control Unit, combined with features in Logger Pro, makes control of electrical devices, such as buzzers, lights, motors, pumps, and relays, both straightforward and flexible. The DCU is a great way to introduce hands-on STEM
Go Direct* Drop Counter, precisely records the number of drops of titrant added during a titration and then automatically converts it to volume, Accurate drop counting at rates up to 6 drops/s, Dimensions: 15.5x4.5x1.8 cm, Opening for drops: 3 cm, Ring stand opening: 16 mm
Go Direct* Melt Station, accurately determines the melting temperature of solid substances, Body Dimensions: 9 cm x 9 cm x 24 cm, Base Dimensions: 13 cm x 15 cm x 1.5 cm, Range: Ambient to 260 deg C, Lighting of control dial: Red LED, Blue LED, Yellow LED, Weight: 1.0 kg
Go Direct* pH Sensor, is a general-purpose pH sensor used to monitor pH of aqueous solutions, pH range: 0-14, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Shaft diameter: 12 mm OD, Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Go Direct* Gas Pressure Sensor, measures the absolute pressure of a gas, Specifications: Range: 0 to 400 kPa, Resolution: 0.03 kPa, Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa, Connections: Wireless Bluetooth, Wired USB
Go Direct* Wide-Range Temperature Probe, with Micro USB Cable, -20degC to 330degC Temperature, Temperature sensing element Platinum RTD (100 omega), Maximum temperature that the sensor can tolerate without damage 380degC, Dimension: 28x17 cm
Go Direct* Rotary Motion Sensor, Resolution: 1deg or 0.25deg, Optical Encoder: Bidirectional, quadrature encoder, Maximum Speed: 30 rev/s at 1deg resolution, 7.5 rev/s at 0.25deg resolution, with Wireless: Bluetooth Connections, Wired: USB Connection
Go Direct* Radiation Monitor, detects alpha, beta, gamma, and X-ray radiation, Sensor: LND 712 (or equivalent) halogen-quenched GM tube with a mica end window, 1.5 to 2.0 mg/cm2 thick, Red LED blinks on radiation detection, Optional audio signal on radiation detection
Go Direct* ORP (Oxidation-Reduction Potential) Sensor, measures the ability of a solution to act as an oxidizing or reducing agent, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Storage solution: pH-4/KCl solution, Temperature range: 0 to 60 degree 'C, 12 mm OD
Go Direct* Motion Detector, uses ultrasound to measure the position, velocity, and acceleration of moving objects, Maximum data collection rate: 30 samples/s, Distances measured from 15 cm to 2.5 m, Temperature compensated, 1/4-20 threaded hole, 1.5 m USB cable
Go Wireless* Heart Rate sensors, ideal for continuously monitoring heart rate before, during, and after exercise or while a person is stationary, Recommended for College, High School, and Middle School Science
Go Direct* CO2 Gas Sensor, CO2 Sensor Range: 0-100,000 ppm, Resolution: 1 ppm CO2, with Wireless: Bluetooth, Wired: USB connections,Study the effect of temperature on cell respiration or metabolism of organisms, Dimension: 38x28mm, Total length: 155 mm
Go Direct* Current Probe User Manual, Probe range: +/-1 A and +/-0.1 A, 300 mA Li-Poly Battery, 24 hours Battery life, 500 full charge cycles (several years depending on usage) Battery life (long term), 1.5 A and 0.5 A non-damaging current, volt: +/-10 V
Go Direct* Optical Dissolved Oxygen Probe, with Micro USB Cable, Range: 0 to 20 mg/L, 0 to 300%, Measure primary productivity or biological/biochemical oxygen demand, Explore the interdependence of plants and animals, Monitor watersheds over time
HOBO* Pendant* G Data Logger, 64K bytes, Measure 3-dimensional motion, such as sports activity or medical therapy compliance, users can measure acceleration and angular displacement in 1, 2 or 3 axes, Data readout in less than 30 seconds
MX Gateway HOBOlink Data Plan, for MX Gateway, ideal for obtaining remote access to data from multiple HOBO MX data loggers monitoring indoor environmental conditions in office buildings, residential environments, warehouses, indoor growing facilities
HOBOnet Manager, is installed in an RX3000 station, 900 MHz wireless mesh self-healing technology, 450 to 600 meter (1,500 to 2,000 feet) wireless range and up to five hops, Up to 50 wireless sensors per RX3000, Plugs into RX3000 Flex Port
HOBO* Pendant* Temperature/Light 64K Data Logger, 64K bytes, two-channel temperature and relative light level data logger, Materials: Polypropylene case; stainless steel screws; Buna-N o-ring, Waterproof housing for wet or underwater use
Eight Channel Biopotential Amplifier, allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single exercising or resting subject, with LabScribe Recording and Analysis Software, Portable, USB
Isolated ECG/EMG/GSR Biopotential Recorder, allows recording of up to three channels of ECG, EMG or EEG as well as GSR, connects to the subject by snap-leads to pre-gelled AG/AgCl electrodes, also capable of mar
HOBO* Pro v2 External Temperature/Relative Humidity Data Logger, weatherproof data logger with an external Temperature and Relative Humidity sensor on a 6-foot cable for fast sensor response and deployment in tight spaces