My Account Menu
United States
 
Order Entry
Orders LinkContactUsLinkComponent
My Account Menu

Vernier® Nitrate Ion-Selective Electrode

Vernier® Nitrate Ion-Selective Electrode

 


 

Measure the concentration of nitrate in aqueous samples.

  • The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode

Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample.

Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.

Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.

Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.

For educational use only.

 

 

  • Catalog No:
  • 470120-638
  • Range:
  • 1 - 10000 mg/L or ppm, pH range: 2.5 - 11;
    Temperature range: 0...50 °C (no temperature compensation)
  • Accuracy:
  • ±10% of full scale (calibrated 1 to 100 mg/L)
  • Dimensions:
  • Electrode length: 155 mm;
    Body diameter: 12 mm;
    Cap diameter: 16 mm;
    Cable length: 100 cm

 

Catalog No
  • 7
  • Range
  • 1 - 10000 mg/L or ppm, pH range: 2.5 - 11;
    Temperature range: 0...50 °C (no temperature compensation)
  • Accuracy
  • ±10% of full scale (calibrated 1 to 100 mg/L)
  • Dimensions
  • Electrode length: 155 mm;
    Body diameter: 12 mm;
    Cap diameter: 16 mm;
    Cable length: 100 cm
  • Product Family Options

     

    •  
       
    • 470120-638
      Vernier Nitrate Ion-Selective Electrode
         
         
      Each
      Each - $349.99
      $349.99
      Each
         $349.99

       : NO3-BTA
       
       
      Specifications
      Cat. No.
      470120-638
      Range
      1 - 10000 mg/L or ppm, pH range: 2.5 - 11;
      Temperature range: 0...50 °C (no temperature compensation)
      Accuracy
      ±10% of full scale (calibrated 1 to 100 mg/L)
      Dimensions
      Electrode length: 155 mm;
      Body diameter: 12 mm;
      Cap diameter: 16 mm;
      Cable length: 100 cm
    • 470219-308
      Replacement Go Direct™ module for Nitrate ion-selective electrode
         
         
      Each
      Each - $104.99
      $104.99
      Each
         $104.99

       : NO3-MOD
       
       
      Specifications
      Cat. No.
      470219-308
      Range
      Accuracy
      Dimensions