Large Needle Electroscope, 1.5lbs, 7.0x6.0x4.0 in, ideal for classroom demonstrations of electrostatic principles, A light-weight metal vane, used as a pointer in the electroscope. A transparent scale, provided to measure the angle of the deflection
Time of Flight Pad sensor to precisely measure how long a projectile has been in motion, determine the launch speed of a projectile, along with the time the projectile is in flight, allow students to see just how kinematic calculations work in rea
Accessories for vibration generator (U56001) for demonstrating standing longitudinal waves in a coil spring. Consisting of angled stand rod, coil spring and connector pin for attachment of the spring to the vibration generator.
Balance kit, package includes an air core solenoid and a current balance for demonstrating and measuring the small force experienced by a conductor carrying an electric current in a magnetic field, one half of the current balance is placed inside the solenoid
Pascalft s Law Apparatus, Weight: 3.3lb, Length: 13.0in, Width: 8.7in, Height: 9.4in, Consists of a moulded plastic base into top of which may be screwed one of a set of four vases of differing shape & a movable index on vertical rod enables the height of water
Boyle's law Horizontal apparatus, A horizontally mounted acrylic tube having a graduated scale (0-300cm3) along one side. A gas tap closes the tube. Pressure gauge is present next to gas tap.
Tangent Galvanometer, Features copper magnet wire, adjustable potentiometer, compass and non-magnetic stand. Measure an electric current by determining the magnitude and direction of the horizontal component of Earths magnetic field
Go Direct* Hand Dynamometer, Measure grip strength, pinch strength, and muscle fatigue wirelessly, Resolution: 0.1 N, Range: 0 to 600 N, Safety Range (maximum force without damage done to sensor): 0 to 850 N, Connections Wireless: Bluetooth, Wired: USB
Youngs Modulus of Wires Apparatus, Frame made of cast iron, Searle s Pattern. Complete with ceiling bracket having two self-centering chucks and tension weight.Searle s Pattern.
Go Direct* Ethanol Vapor Sensor, Measure the concentration of ethanol in air above an aqueous sample with Go Direct Ethanol Vapor, Range: 0% to 3%, Response Time: 90% of full scale in 60 seconds, Connections: Wireless: Bluetooth, Wired: USB
Cover, Material: Rugged ABS plastic, For E/M Apparatus, Protects the bulb of the e/M Apparatus during transport, Provides viewing of the e/M Apparatus in lit classrooms
Number, Measurement and Space, module establishes equivalence of sets by a one-to-one exchange of objects. Eg Upsetting equivalance (destroying conservation of numbers) by adding one object to a set, or taking one away, helps introduce vocabulary for comparing quantity
Youngs Modulus Supplementary Set, 12 Flat Bars Made Of Steel (Thickness: 2 / 3 mm), 6 Flat Bars Made Of Aluminium (Thickness: 3 mm), With The Effective Lengths Of 200, 300 And 400 mm And The Widths Of 10 And 20 mm For Measurement Of Elastic Deformation.
Component Balance, Measuring Range: 0-0.3 N, Diameter Of The Scale: 170 mm, Dimensions: Approx. 350X220 mm2, Rod Diameter: 10 mm, Weight: Approx. 0.9 Kg, Scales For Measuring Components With Holding Mechanism For Measuring Air Resistance And Buoyancy Of Bodies From Set.
Free Fall Apparatus Economy, for determination of the gravitational constant ft gft, This kit has a wooden base, 1.1m rod and a movable electro magnet, can be moved anywhere on the rod, when the ball is released the timer is triggered and stopped one the ball his landed on the base
Nexpensive, compact counter for measuring milliseconds. Each count is started and stopped by a signal at the input sockets. The device is automatically reset to zero each time it is restarted.
Vibration generator for exciting oscillating and waves mechanically, e.g. in coil springs, a rubber cord, a wire ring or a Chladni plate. In robust plastic housing including mounting pin with 4-mm socket for attaching accessories
Lighting Kit, Suitable for opto electronic scanning of light and dark markings on moving objects or in conjunction with a reflecting foil to form a wide spaced obstruction sensor. The intensity of the laser beam is adjusted automatically according to the distance of the object
Coulombmeter With Rechargeable Battery, Power Supply: 9 V Rechargeable Battery Via Dc Co-Axial Power Socket, Load Current:Max. 500 Ma, Connectors: 4-mm Safety Sockets, Dimensions: 105 X 75 X 35 mm3 Approx, Consumption Can Be Displayed By Means Of A Voltmeter.
Photoconductivity, Multipurpose power supply. Electrical safety tested. Marked analyzer & polarizer for angle measurement. Photo current is studied as a function of the voltage applied to the photo resistor at a constant irradiance.
Ct Measuring Trough, Material: Acrylic, Thickness Of Sides: 4 mm Approx, Dimensions: 430X150X150 mm3, Made Of Thin Transparent Plastic, Includes Several Special Fittings For Attaching And Connecting ultrasonic Sensors To The Sides Of The Trough.
Digital Counter For event counting, a fixed counting period can be programmed in a range from 0.1 ms to 99999 s. Counter events (e.g. start or stop) can either be triggered by a signal to the input sockets or manually via switches. The unit includes a plug-in power supply.