Go Direct* Temperature Probe, is a rugged, general-purpose temperature sensor that students can use to monitor temperature, Temperature range: -40 to 125 deg C, Handle temperature range: -10 to 45 deg C, Resolution: 0.07 deg C, Connections: Wireless Bluetooth, Wired USB
Go Direct* CO2 Gas Sensor, CO2 Sensor Range: 0-100,000 ppm, Resolution: 1 ppm CO2, with Wireless: Bluetooth, Wired: USB connections,Study the effect of temperature on cell respiration or metabolism of organisms, Dimension: 38x28mm, Total length: 155 mm
Go Direct* Motion Detector, uses ultrasound to measure the position, velocity, and acceleration of moving objects, Maximum data collection rate: 30 samples/s, Distances measured from 15 cm to 2.5 m, Temperature compensated, 1/4-20 threaded hole, 1.5 m USB cable
Go Direct* Tris-Compatible Flat pH User Manual, used for any lab or demonstration that can be done with a traditional pH meter, including acid-base titrations, monitoring pH in an aquarium, and investigating the water quality of streams and lakes
Go Direct* Force and Acceleration Sensor, couples a 3-axis accelerometer with a stable and accurate force sensor that measures forces as small as +/- 0.1 N and up to +/- 50 N, Acceleration: 3 axis, +/- 16 g, Gyroscope: 3 axis, 2000 deg /s
Go Direct* pH Sensor, is a general-purpose pH sensor used to monitor pH of aqueous solutions, pH range: 0-14, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Shaft diameter: 12 mm OD, Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Go Direct* Gas Pressure Sensor, measures the absolute pressure of a gas, Specifications: Range: 0 to 400 kPa, Resolution: 0.03 kPa, Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa, Connections: Wireless Bluetooth, Wired USB
Go Direct* Optical Dissolved Oxygen Probe, with Micro USB Cable, Range: 0 to 20 mg/L, 0 to 300%, Measure primary productivity or biological/biochemical oxygen demand, Explore the interdependence of plants and animals, Monitor watersheds over time
Go Wireless* Heart Rate sensors, ideal for continuously monitoring heart rate before, during, and after exercise or while a person is stationary, Recommended for College, High School, and Middle School Science
Go Direct* Sensor Cart, Green, for College, High School, and Middle School Science, features built-in, wireless sensors for one-dimensional dynamics and kinematics experiments, directly connects wirelessly via Bluetooth, Position resolution: 0.25 mm
Disposable Bacterial Filter, disposable microbacterial filter significantly reduces need to sterilize your spirometers flow head, 30 mm ID opening allows for an easy, air-tight fit to the flow head
Go Direct* Colorimeter, measures absorbance or transmittance of a liquid sample, Specifications: Range: 0 to 3 (absorbance), Useful range: 0.05 to 1.0 (absorbance), 90% to 10% transmittance (%T), Wavelengths: 430 nm, 470 nm, 565 nm, 635 nm, Connections: Bluetooth, USB
Go Direct* Photogate, double-gate sensor that includes two photogates built into the arms of the sensor, which accurately measures velocity and acceleration, Infrared source: Peak at 880 nm, Gate width: 77.5 mm, Battery: 300 mAh Li-Poly Rechargeable
Noseclip, plastic, foam-padded noseclips help increase the accuracy of spirometry results by eliminating the escape of air through the nostrils during testing
camera adapter, 0.35X C-mount for 1/3inch chip sensors, allows Moticams to connect with Motic BA and AE2000/AE31E trinocular microscopes, Compatible with the following cameras: Moticam 2, Moticam X, Moticam X2, Moticam 1080, Moticam BTU 10
Mouthpiece, Disposable, For a more sterile environment, use the cardboard mouthpieces to help eliminate the spreading of contagious material between students
PH Buffer Capsule for calibration of pH, contains four capsules for each of the 4, 7, and 10 pH buffers, making a total of 12 capsules. The set also includes a small bottle of universal indicator with mold inhibitor, Has to be added to 100 ml of distilled water
Go Direct* Voltage Probe, combines a wide input voltage range and high precision, Specifications: Input voltage range: +/-15.0 V, Maximum voltage on any input: +/-15 V, Typical resolution: 0.5 mV, Power: Internal rechargeable battery, Wireless: Bluetooth, Wired: USB
Go Direct* Surface Temperature Sensor, Range: -25 to 125 deg C, Accuracy: +/-0.5 degC, Response time (from 25 C to 100 deg C in water): 5 seconds, Dimension: 6.8x2.25x1.3cm, Cable length: 1 m, with Wireless: Bluetooth, Wired: USB Connection
Go Direct* Conductivity Probe, determines the ionic content of an aqueous solution by measuring its electrical conductivity, Range: 0 to 20,000 uS/cm, Temperature compensation: Automatic from 5 to 35 deg C, can be turned off, Temperature range: 0 to 80 deg C
Go Direct* Drop Counter, precisely records the number of drops of titrant added during a titration and then automatically converts it to volume, Accurate drop counting at rates up to 6 drops/s, Dimensions: 15.5x4.5x1.8 cm, Opening for drops: 3 cm, Ring stand opening: 16 mm