Go Direct* Temperature Probe, is a rugged, general-purpose temperature sensor that students can use to monitor temperature, Temperature range: -40 to 125 deg C, Handle temperature range: -10 to 45 deg C, Resolution: 0.07 deg C, Connections: Wireless Bluetooth, Wired USB
Go Direct* CO2 Gas Sensor, CO2 Sensor Range: 0-100,000 ppm, Resolution: 1 ppm CO2, with Wireless: Bluetooth, Wired: USB connections,Study the effect of temperature on cell respiration or metabolism of organisms, Dimension: 38x28mm, Total length: 155 mm
Go Direct* Motion Detector, uses ultrasound to measure the position, velocity, and acceleration of moving objects, Maximum data collection rate: 30 samples/s, Distances measured from 15 cm to 2.5 m, Temperature compensated, 1/4-20 threaded hole, 1.5 m USB cable
Fan Cart large fan on a light-weight cart, offers students the ability to perform kinematics and dynamics experiments with constant acceleration, variable mass, variable thrust, and variable thrust angle
Pre-sterilized, Compatible with the widest range of pipets, Maximizes sample recovery with low binding resin, Improves ergonomics by reducing the force required to attach and eject a tip, Autoclavable at 15 psi, 122 deg C for 15 minutes, Length: 50.75 mm, Volume: 20 ul
Go Direct* Force and Acceleration Sensor, couples a 3-axis accelerometer with a stable and accurate force sensor that measures forces as small as +/- 0.1 N and up to +/- 50 N, Acceleration: 3 axis, +/- 16 g, Gyroscope: 3 axis, 2000 deg /s
Go Direct* Optical Dissolved Oxygen Probe, with Micro USB Cable, Range: 0 to 20 mg/L, 0 to 300%, Measure primary productivity or biological/biochemical oxygen demand, Explore the interdependence of plants and animals, Monitor watersheds over time
Go Direct* Gas Pressure Sensor, measures the absolute pressure of a gas, Specifications: Range: 0 to 400 kPa, Resolution: 0.03 kPa, Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa, Connections: Wireless Bluetooth, Wired USB
Go Direct* pH Sensor, is a general-purpose pH sensor used to monitor pH of aqueous solutions, pH range: 0-14, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Shaft diameter: 12 mm OD, Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Fiber Optics Voice and Data Kit, fiber optics communications, Transmit your voice or a 1kHz signal through the fiber optic cable to a fiber optic receiver, components: including PC boards; microphone; speaker and fiber optic cable, with Transmitter and receiver
Go Direct* SpectroVis* Plus Spectrophotometer, quickly measures a full wavelength spectrum, Wavelength Range: 380 nm-950 nm, Support for fluorescence: Two excitation sources centered at 405 nm and 500 nm, Dimensions: 16 cm x 10 cm x 5 cm
Pre-sterilized, Compatible with the widest range of pipets, Maximizes sample recovery with low binding resin, Improves ergonomics by reducing the force required to attach and eject a tip, Autoclavable at 15 psi, 122 deg C for 15 minutes, Length: 59.54 mm, Volume: 200 ul
Go Direct Respiration Belt, Range: 0-50 N, Resolution: 0.01 N, Response time: 50 ms, Maximum chest circumference: 140 cm, with Wireless: Bluetooth Connections, Wired: USB Connection, Measure steps and step rate during a study with the built-in pedometer
Go Direct* Colorimeter, measures absorbance or transmittance of a liquid sample, Specifications: Range: 0 to 3 (absorbance), Useful range: 0.05 to 1.0 (absorbance), 90% to 10% transmittance (%T), Wavelengths: 430 nm, 470 nm, 565 nm, 635 nm, Connections: Bluetooth, USB
Go Wireless* Heart Rate sensors, ideal for continuously monitoring heart rate before, during, and after exercise or while a person is stationary, Recommended for College, High School, and Middle School Science
Go Direct* Conductivity Probe, determines the ionic content of an aqueous solution by measuring its electrical conductivity, Range: 0 to 20,000 uS/cm, Temperature compensation: Automatic from 5 to 35 deg C, can be turned off, Temperature range: 0 to 80 deg C
Kit big data and bone fracture risk, Investigate factors that could be used to predict bone fracture risk. Conduct simulated medical tests, then record and analyze data, with 5 labeled droppers, unassembled 10-pack contains all materials to assemble 10 kits
Go Direct* Drop Counter, precisely records the number of drops of titrant added during a titration and then automatically converts it to volume, Accurate drop counting at rates up to 6 drops/s, Dimensions: 15.5x4.5x1.8 cm, Opening for drops: 3 cm, Ring stand opening: 16 mm
Go Direct* Voltage Probe, combines a wide input voltage range and high precision, Specifications: Input voltage range: +/-15.0 V, Maximum voltage on any input: +/-15 V, Typical resolution: 0.5 mV, Power: Internal rechargeable battery, Wireless: Bluetooth, Wired: USB
Go*Temp, Temperature sensor, Collect temperature data directly through the USB port of a computer, teacher package, temperature graph plotted in real time
Go Direct* Rotary Motion Sensor, Resolution: 1deg or 0.25deg, Optical Encoder: Bidirectional, quadrature encoder, Maximum Speed: 30 rev/s at 1deg resolution, 7.5 rev/s at 0.25deg resolution, with Wireless: Bluetooth Connections, Wired: USB Connection
Adapter allows to be connected to a computer for data collection using Logger Pro or Logger Lite software, It has an USB Mini-A receptacle that connects to EasyTemp or EasyLink and a standard-A plug that connects to computer