Go Direct* Temperature Probe, is a rugged, general-purpose temperature sensor that students can use to monitor temperature, Temperature range: -40 to 125 deg C, Handle temperature range: -10 to 45 deg C, Resolution: 0.07 deg C, Connections: Wireless Bluetooth, Wired USB
Go Direct* CO2 Gas Sensor, CO2 Sensor Range: 0-100,000 ppm, Resolution: 1 ppm CO2, with Wireless: Bluetooth, Wired: USB connections,Study the effect of temperature on cell respiration or metabolism of organisms, Dimension: 38x28mm, Total length: 155 mm
Go Direct* Optical Dissolved Oxygen Probe, with Micro USB Cable, Range: 0 to 20 mg/L, 0 to 300%, Measure primary productivity or biological/biochemical oxygen demand, Explore the interdependence of plants and animals, Monitor watersheds over time
Go Direct* pH Sensor, is a general-purpose pH sensor used to monitor pH of aqueous solutions, pH range: 0-14, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Shaft diameter: 12 mm OD, Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Go Direct Respiration Belt, Range: 0-50 N, Resolution: 0.01 N, Response time: 50 ms, Maximum chest circumference: 140 cm, with Wireless: Bluetooth Connections, Wired: USB Connection, Measure steps and step rate during a study with the built-in pedometer
Go Direct* Conductivity Probe, determines the ionic content of an aqueous solution by measuring its electrical conductivity, Range: 0 to 20,000 uS/cm, Temperature compensation: Automatic from 5 to 35 deg C, can be turned off, Temperature range: 0 to 80 deg C
Go Direct* Voltage Probe, combines a wide input voltage range and high precision, Specifications: Input voltage range: +/-15.0 V, Maximum voltage on any input: +/-15 V, Typical resolution: 0.5 mV, Power: Internal rechargeable battery, Wireless: Bluetooth, Wired: USB
Go Direct* Rotary Motion Sensor, Resolution: 1deg or 0.25deg, Optical Encoder: Bidirectional, quadrature encoder, Maximum Speed: 30 rev/s at 1deg resolution, 7.5 rev/s at 0.25deg resolution, with Wireless: Bluetooth Connections, Wired: USB Connection
Go Direct* ORP (Oxidation-Reduction Potential) Sensor, measures the ability of a solution to act as an oxidizing or reducing agent, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Storage solution: pH-4/KCl solution, Temperature range: 0 to 60 degree 'C, 12 mm OD
Go Direct* Acceleration Sensor, Low acceleration: +/-157 m/s2, High acceleration: +/-1,960 m/s2, Altimeter: -1,800 m to 10,000 m, Angle: +/-180 deg, with Wireless: Bluetooth Connections, Wired: USB Connection, Slip it into your pocket and pirouette or ride a half-pipe