76 Results for: "volatile organic analysis containers"
CrossLab Torches for ICP-MS, Agilent Technologies
Supplier: AGILENT TECHNOLOGIES, INC (CSD)
One-piece quartz torches for Agilent ICP-MS, including standard and torches for organic solvents.
Expand 1 Items
I-CHEM™ Wide Mouth Jars, Amber Glass, with Caps, Thermo Scientific
Supplier: Thermo Scientific
For use with UV-light sensitive samples.
Expand 18 Items
VWR® TraceClean® Vials with Chemical Preservative
Supplier: VWR International
Type I borosilicate glass vials contain a chemical preservative to maintain sample integrity until volatile organic analysis can be performed.
Expand 6 Items
Glass Vials, C&G Containers
Supplier: C&G Containers
These glass vials from C&G Containers are designed primarily for the collection and testing of solid samples for Volatile Organic Analysis and Total Petroleum Hydrocarbons (TPH), and for the collection and testing of aqueous samples for Total Organic Carbon (TOC).
Expand 6 Items
Glass Vials, C&G Containers
Supplier: C&G Containers
These glass vial are used primarily for the collection and testing of aqueous samples for Volatile Organic Analysis and Total Petroleum Hydrocarbons (TPH) and for the collection and testing of aqueous samples for Total Organic Carbon (TOC). Secondary uses include containment of extracts. Please refer to the applicable Certificate of Analysis for certified analytes and corresponding reporting limits.
Expand 1 Items
Ethyl acetate ≥99.9%, CHROMASOLV™ for pesticide residue analysis, Riedel-de Haën™
Supplier: Honeywell Research Chemicals
Ethyl Acetate is an organic solvent with the structure CH3-COO-CH2-CH3 (C4H8O2). This colorless liquid has a characteristic sweet odor. In the laboratory, mixtures containing ethyl acetate are used in column chromatography and extractions. Ethyl acetate does not work well as a reaction solvent because it is prone to hydrolysis and transesterification. Ethyl acetate is volatile at room temperature and has a boiling point of 77 °C. Suitable for GC and Pesticide Residue Analysis.
Expand 2 Items
GsBP®-5MS Non-Polar GC Columns, GS-Tek
Supplier: General Separation Technologies, Inc.
Typical Application: Acidic/neutral drugs, alkaloids, amines and nitriles, amphetamine and methamphetamine, antiepileptic, basic drugs, chlorinated pesticides, EPA method 508, CLP standard, semivolatile organics, diesel fuel, drug of abuse, endocrine disruptors: alkyl phenols, endocrine disruptors: phthalate, EPA 608.1, EPA air analysis method TO-15, EPA method 525.2, EPA method 551.1, EPA method 610, EPA method 8061 (phthalate ester), EPA method 8270, EPA-625 phenols, flavor mixture, food packaging volatiles, formaldehyde, 50ppb, fragrance allergens, gasoline, halogenated compounds, local anesthetics, nitrogen/phosphorus containing pesticides, EPA 507, organochlorine pesticides, organochlorine pesticides II EPA method 8081A, organohalide pesticides in water, EPA 505, organophosphorous pesticides I EPA 8141A, phenols, I and II, polybrominated diphenyl esters (PBDE), polyethyleneamines, polynuclear aromatic hydrocarbons (PAHs), semivolatile compounds, semivolatile organics, substituted anilines, sulfur in air, trace active amines, 10 ng on-column, tricyclic antipsychotics, urine drug screen, US EOA method 8270D mix.
Expand 67 Items
VWR® TraceClean® Vials, Amber
Supplier: VWR International
These TraceClean® glass jars are used primarily for the collection of and testing of aqueous samples for Volatile Organic Analysis and Total Petroleum Hydrocarbons (TPH).
Expand 5 Items
VWR® TraceClean® Vials, Clear
Supplier: VWR International
These TraceClean® glass jars are used for the collection of and testing of aqueous samples for Volatile Organic Analysis and Total Petroleum Hydrocarbons (TPH).
Expand 9 Items
Borosilicate Glass VOA Vials, Sun Sri
Supplier: Thermo Scientific
VOA vials are made from clear borosillicate glass, and are used for the analysis of volatile organic compounds.
Expand 1 Items
Precleaned Sample Vials with PTFE Lined Screw Cap, Chemglass
Supplier: Chemglass
Vials are precleaned and certified for volatile organic analysis.
Expand 4 Items
Borosilicate Glass VOC Vials, DWK Life Sciences
Supplier: DWK Life Sciences (KIMBLE)
These autosampler vials with open top caps are ideal for the analysis of volatile organic compounds.
Expand 1 Items
Precleaned VOA Vials, Environmental Express®
Supplier: Environmental Express
These volatile organic analysis (VOA) vials are made of borosilicate glass. Choose from an open-top cap (0.125" thick PTFE/silicone septa) or closed-top style cap in a variarty of capacities and clear or amber glass.
Expand 20 Items
Atlantic City (AC) Round Glass Bottles, Clear, C&G Containers
Supplier: C&G Containers
These jars are used primarily for the collection of of soil, sediments, and slurry media for testing Semi-volatiles, pesticides, PCBs, diesel range Organics, TPH, metals, and phenolics.
Expand 8 Items
Straight Side Glass Bottles, Clear, C&G Containers
Supplier: C&G Containers
These glass jars are used primarily for the collection of liquid media, soil, sediments, and slurry media for testing Semi-volatiles, Pesticides, PCBs, Diesel Range Organics, TPH, Metals, and Phenolics
Expand 30 Items
524 Rev. 4.0 Volatile Organics Kit (2,000 µg/mL), Restek
Supplier: Restek
Contains 1 ml each of these mixtures: 524 internal standard/surrogate mix, 502.2 calibration mix #1, 502.2 calibration mix #2, 502.2 calibration mix #3, 502.2 calibration mix #4, 502.2 calibration mix #5, 502.2 calibration mix #6, 524 calibration mix #7a, 524 calibration mix #7b, 524 calibration mix #8.
Expand 1 Items
SV Calibration Mix #1 (5 Components), Restek
Supplier: Restek
Contains: Benzyl alcohol (100-51-6); 4-Chloroaniline (106-47-8); 2-Nitroaniline (88-74-4); 3-Nitroaniline (99-09-2); 4-Nitroaniline (100-01-6).
Expand 1 Items
Mayo Glass Bottles, Clear, C&G Containers
Supplier: C&G Containers
These glass jars are used primarily for the collection of soil and slurry media for testing Semi-volatiles, Pesticides, PCBs, diesel range organics, TPH, metals, and phenolics.
Expand 7 Items
Boston Round Glass Bottles, Narrow Mouth, Amber, C&G Containers
Supplier: C&G Containers
These glass jars are used primarily for the collection of liquid media, for testing semi-volatiles (light sensitive compounds), pesticides, PCBs, diesel range organics, TPH, metals, and phenolics.
Expand 17 Items
Wide Mouth Glass Jugs, Clear, C&G Containers
Supplier: C&G Containers
These glass jugs are used primarily for the collection of benthic organisms and the collection of water samples for mulitple analyte testing.
Expand 1 Items
Boston Round Glass Bottles, Narrow Mouth, Clear, C&G Containers
Supplier: C&G Containers
These glass jars are used primarily for the collection of liquid media, for testing semi-volatiles, pesticides, PCBs, diesel range organics, TPH, metals, and phenolics.
Expand 22 Items
VOA Internal Standard Mix (3 Components), Restek
Supplier: Restek
Mix contains: Bromochloromethane (74-97-5), 1,4-Difluorobenzene (540-36-3), Chlorobenzene-d5 (3114-55-4).
Expand 1 Items
VOA Surrogate Spike Mix (3 components), Restek
Supplier: Restek
Mix contains: 1-Bromo-4-fluorobenzene (BFB) (460-00-4), 1,2-Dichloroethane-d4 (17060-07-0) and Toluene-d8 (2037-26-5).
Expand 1 Items
EPA method 8260 Volatile Organics Standards Kit, Restek
Supplier: Restek
Standards are packaged at a concentration of 2500 µg/mL (except 2000 µg/mL for 502.2 calibration mixes and system performance check mix) in purge-and-trap-grade methanol at a concentration in 1 mL ampoules.
Expand 1 Items
SV Calibration Mix #7 (3 Components), Restek
Supplier: Restek
SV Calibration mix contains 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene.
Expand 1 Items
VOA Calibration Mix #5 (gases) (4 components), Restek
Supplier: Restek
Mix contains: Bromomethane (methyl bromide) (74-83-9), Chloroethane (ethyl chloride) (75-00-3), Chloromethane (methyl chloride (74-87-3), Vinyl chloride (75-01-4).
Expand 1 Items
VOA Screening Mix #2 (2 Components), Restek
Supplier: Restek
Mix contains: (C9) n-Nonane (111-84-2), (C12) n-Dodecane (112-40-3).
Expand 1 Items
Wide Mouth Glass Packer Bottles, Amber, C&G Containers
Supplier: C&G Containers
These glass jars are used primarily for the collection of liquid media, soil, sediments, and slurry media for testing Semi-volatiles (Light Sensitive compounds), Pesticides, PCBs, Diesel Range Organics, TPH, Metals, and Phenolics
Expand 26 Items
VOA Calibration Mix #1 (Ketones) (4 Components), Restek
Supplier: Restek
Mix contains Acetone (67-64-1), 2-Butanone (MEK) (78-93-3), 2-Hexanone (591-78-6), 4-Methyl-2-pentanone (MIBK) (108-10-1).
Expand 1 Items
VOA Calibration Mix #2 (7 Components), Restek
Supplier: Restek
Mix contains: Benzene (71-43-2), Carbon disulfide (75-15-0), Ethylbenzene (100-41-4), Toluene (108-88-3), vinyl acetate (108-05-4), o-Xylene (95-47-6), p-Xylene (106-42-3).