Order Entry
United States
Orders LinkContactUsLinkComponent
1762 results for "Labeling and Detection"

1762 Results for: "Labeling and Detection"

Sort By
Amersham ECL Direct Labeling and Detection System, Cytiva

Amersham ECL Direct Labeling and Detection System, Cytiva

Supplier: Cytiva

ECL Direct Nucleic Acid Labeling and Detection Systems are based on the direct labeling of DNA or RNA probes with horseradish peroxidase (HRP) in a simple 20 minute chemical reaction. The resulting probe can be used without purification. Detection is achieved by generation of light via the HRP-catalyzed breakdown of luminol.

Expand 2 Items
Loading...
Nucleic acid labelling and Detection System, Amersham ECL Direct™

Nucleic acid labelling and Detection System, Amersham ECL Direct™

Supplier: Cytiva

ECL Direct™ nucleic acid labelling and detection systems are based on the direct labelling of DNA or RNA probes with horseradish peroxidase (HRP) in a simple 20 minute chemical reaction. The resulting probe can be used without purification. Detection is achieved by generation of light via the HRP-catalysed breakdown of luminol. Suitable for fast and easy detection of medium to high target amounts in applications such as colony/plaque screens, dot blots and PCR product analyses.

Expand 2 Items
Loading...
Biotin NTA biodetection

Biotin NTA biodetection

Supplier: AAT Bioquest

Biotin NTA (BNTA), a biotin-labeled nitrilotriacetic acid, is widely used to detect histidine-tagged proteins immobilized on nitrocellulose membranes with the detection limite of ~0.1 pmol.

Expand 1 Items
Loading...
Nucleic acid labelling and detection system, AlkPhos Direct™

Nucleic acid labelling and detection system, AlkPhos Direct™

Supplier: Cytiva

AlkPhos Direct™ Labelling and detection systems are based on the rapid, direct labelling of DNA or RNA probes with thermostable alkaline phosphatase. AlkPhos Direct™ combines the convenience of direct enzyme labelling (no blocking or antibody stages) with those of alkaline phosphatase detection (long light output and high sensitivity).

Expand 3 Items
Loading...
Polyester (B-855), Metal Detectable Polyester (B-854) Labels, type B30,  ToughWash®, Brady

Polyester (B-855), Metal Detectable Polyester (B-854) Labels, type B30, ToughWash®, Brady

Supplier: Brady Worldwide

ToughWash® material polyester film with acrylic adhesive is a strong, print-on-demand label specially formulated for the Food and Beverage processing industry.

Expand 16 Items
Loading...

CloneDetect, Molecular Devices

Supplier: Molecular Devices

Screen and select high value mammalian clones with label-free, in situ detection of IgG secretion with the ClonePix system, and other cell analyzers with a green fluorescent channel.

Expand 1 Items
Loading...
DBCO-Cy5 fluorescent probe

DBCO-Cy5 fluorescent probe

Supplier: AAT Bioquest

This azadibenzocyclooctyne-cyanine dye derivative is a versatile labeling reagent for detection of azide containing molecules or compounds.

Expand 1 Items
Loading...
DBCO-Cy3 fluorescent probe

DBCO-Cy3 fluorescent probe

Supplier: AAT Bioquest

This azadibenzocyclooctyne-cyanine dye derivative is a versatile labeling reagent for detection of azide containing molecules or compounds.

Expand 1 Items
Loading...
Amersham ECL Direct Labeling System, Cytiva

Amersham ECL Direct Labeling System, Cytiva

Supplier: Cytiva

ECL Direct Nucleic Acid Labeling and Detection Systems are based on the direct labeling of DNA or RNA probes with horseradish peroxidase (HRP) in a simple 20 minute chemical reaction. The resulting probe can be used without purification. Detection is achieved by generation of light via the HRP-catalyzed breakdown of luminol.

Expand 1 Items
Loading...
Amersham QuickStain Protein Labeling Kit, Cytiva

Amersham QuickStain Protein Labeling Kit, Cytiva

Supplier: Cytiva

The Amersham™ QuickStain Kit contains a Cy™5 fluorophore and labeling buffer for easy detection of proteins in SDSPAGE gels and on Western blotting membranes. The ready to use Cy5 N-hydroxysuccinimide (NHS) ester and Tris labeling buffer ensure robust and consistent labeling for detection of proteins in diverse samples.

Expand 1 Items
Loading...
Pierce™ Fluor Phosphine Reagents, DyLight™, Thermo Scientific

Pierce™ Fluor Phosphine Reagents, DyLight™, Thermo Scientific

Supplier: Invitrogen

Thermo Scientific DyLight Fluor Phosphine Reagents are phosphine-activated fluorescent dyes for specific labeling and detection of azide-tagged molecules, which enables use of fluorescence imaging in metabolic labeling strategies.

Expand 3 Items
Loading...

LumiGLO Peroxidase Chemiluminescent Substrate

Supplier: KPL

LumiGLO Peroxidase Chemiluminescent substrate is an all-purpose, luminol-based substrate designed for the rapid and sensitive detection of peroxidase labeled-conjugates in Western blotting and ELISA

Expand 3 Items
Loading...

LumiGLO Reserve® Chemiluminescent Substrate, SeraCare

Supplier: KPL

LumiGLO Reserve is a luminol-based chemiluminescent substrate designed for rapid and sensitive detection of peroxidase-labeled conjugates

Expand 3 Items
Loading...
AML Cy5 NHS ester, ReadiCleave™ for reversible fluorescent labeling

AML Cy5 NHS ester, ReadiCleave™ for reversible fluorescent labeling

Supplier: AAT Bioquest

Fluorescence-based methods have many advantages for biological detections in terms of sensitivity.

Expand 1 Items
Loading...
2-NBDG ≥90%

2-NBDG ≥90%

Supplier: AAT Bioquest

2-NBDG is a fluorescently-labeled deoxyglucose analog that is used primarily to directly monitor glucose uptake by living cells and tissues.

Expand 1 Items
Loading...
Biotin maleimide, ReadiView™ biodetection

Biotin maleimide, ReadiView™ biodetection

Supplier: AAT Bioquest

Biotin/avidin complexes are widely applied for a variety of biological detections.

Expand 1 Items
Loading...
Biotin hydrazide, ReadiView™ biodetection

Biotin hydrazide, ReadiView™ biodetection

Supplier: AAT Bioquest

Biotin/avidin complexes are widely applied for a variety of biological detections.

Expand 1 Items
Loading...
Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Red Fluorescence* (50 Tests), AAT Bioquest

Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Red Fluorescence* (50 Tests), AAT Bioquest

Supplier: AAT Bioquest

DNA fragmentation represents a characteristic of late stage apoptosis.

Expand 1 Items
Loading...
D-Biotin-N-succinimidyl ester, ReadiView™ biodetection

D-Biotin-N-succinimidyl ester, ReadiView™ biodetection

Supplier: AAT Bioquest

Biotin/avidin complexes are widely applied for a variety of biological detections.

Expand 1 Items
Loading...
Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Green Fluorescence* (50 Tests), AAT Bioquest

Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Green Fluorescence* (50 Tests), AAT Bioquest

Supplier: AAT Bioquest

DNA fragmentation represents a characteristic of late stage apoptosis.

Expand 1 Items
Loading...
Biotin amine, ReadiView™ biodetection

Biotin amine, ReadiView™ biodetection

Supplier: AAT Bioquest

Biotin/avidin complexes are widely applied for a variety of biological detections.

Expand 1 Items
Loading...
8-Aminopyrene-1,3,6-trisulfonic acid trisodium salt ≥95%

8-Aminopyrene-1,3,6-trisulfonic acid trisodium salt ≥95%

Supplier: AAT Bioquest

This water-soluble reagent has strong green fluorescence with great Stokes shift.

Expand 1 Items
Loading...
Biotin acid, ReadiView™ biodetection

Biotin acid, ReadiView™ biodetection

Supplier: AAT Bioquest

Biotin/avidin complexes are widely applied for a variety of biological detections.

Expand 1 Items
Loading...

SureBlue Reserve™ Microwell Substrate, KPL

Supplier: KPL

SureBlue Reserve™ provides maximum sensitivity for detection of peroxidase labeled conjugates in a microwell format and provides 50% more sensitivity than standard SureBlue™ TMB substrate

Expand 3 Items
Loading...
Amersham™ CyDye™ Value Packs (Bis-Reactive NHS Esters), Cytiva

Amersham™ CyDye™ Value Packs (Bis-Reactive NHS Esters), Cytiva

Supplier: Cytiva

Amersham™ CyDye™ fluors combine exceptional photostability with bright and intense signals, resulting in high sensitivity and a highly reproducible performance at a biologically suitable pH range of 3 to 10.

Expand 1 Items
Loading...
APO-BRDU™ kit, TUNEL Assay

APO-BRDU™ kit, TUNEL Assay

Supplier: Tonbo Biosciences

The APO-DIRECT™ reagent kit provides a two color TUNEL (Terminal deoxynucleotide transferase dUTP Nick End Labeling) assay for labeling DNA breaks and total cellular DNA to detect apoptotic cells by flow cytometry. The kit contains the instructions and reagents required for measuring apoptosis in cells including: positive and negative control cells for assessing reagent performance; washing, reaction and rinsing buffers for processing individual steps in the assay; terminal deoxynucleotidyl tranferase enzyme (TdT), fluorescein isothiocyanate (FITC) deoxyuridine triphosphate (FITC-dUTP) for labeling DNA breaks and PI/RNase A solution for counter staining the total DNA.

Expand 1 Items
Loading...

Pyridoxal hydrochloride

Supplier: Adipogen

For the labeling of amino acids and their detection in picomolar amounts.

Expand 2 Items
Loading...
Anti-BrdU Mouse Monoclonal Antibody (FITC (Fluorescein Isothiocyanate)) [clone: PRB-1]

Anti-BrdU Mouse Monoclonal Antibody (FITC (Fluorescein Isothiocyanate)) [clone: PRB-1]

Supplier: Tonbo Biosciences

The fragmentation of genomic DNA by cellular nucleases during the later stages of apoptosis is also one of the most easily measured features of apoptotic cells. Nuclease activity generates DNA fragments ranging from ~300 bp to 50 bp in length, resulting in a typical DNA ‘laddering’ appearance when analyzed by agarose gel electrophoresis. These fragments have exposed 3’-hydroxyl (OH) ends which can be labeled with bromolated deoxyuridine triphosphates (Br-dUTP). An enzyme, terminal deoxynucleotidyl transferase (TdT), is used to catalyze the template-independent addition of Br-dUTP to the 3’-OH ends of double or single stranded DNA. This method is often called TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling) or end labeling. Sites where the Br-dUTP is incorporated can then be detected with an antibody specific to BrdU. With the APO-BrdUTM Kit cells are first labeled with Br-dUTP, and then sites of incorporation are detected through staining with a FITC anti-BrdU antibody. Samples can then be analyzed via flow cytometry. Samples that are apoptotic will stain brightly with the anti-BrdU antibody due to the substantial number of exposed 3’-OH sites, while cells that are non-apoptotic will not have incorporated significant amounts of Br-dUTP and will stain dimly. The APO-BrdU Kit is shipped in one container and consists of two packages. Upon arrival one should be stored at 2-8°C and the other at -20°C.

Expand 1 Items
Loading...
Pierce™ ONPG (o-nitrophenyl-β-D-galactopyranoside), Thermo Scientific

Pierce™ ONPG (o-nitrophenyl-β-D-galactopyranoside), Thermo Scientific

Supplier: Invitrogen

Thermo Scientific Pierce ONPG is the preferred colorimetric substrate for ELISA applications involving beta-galactosidase (b-Gal) as the reporter enzyme.

Expand 1 Items
Loading...

4-Bromomethyl-6,7-dimethoxycoumarin ≥95%

Supplier: Thermo Scientific Chemicals

Applications: Fluorescent labeling reagent. used in HPLC for the detection of carboxylic acids

Expand 2 Items
Loading...
Sort By
Recommended for You