Order Entry
United States
Orders LinkContactUsLinkComponent
1845 results for "Analytical Standards"

1845 Results for: "Analytical Standards"

Sort By

ICP-MS Interferents B3 without Mercury, 2 µg/ml (2 ppm), SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.

The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.

US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:

• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements

CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

Expand 1 Items
Loading...

ICP-MS Interferents B3 with Mercury, 2 µg/ml (2 ppm), SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.

The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.

US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:

• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements

CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

Expand 1 Items
Loading...
Acclaim™ Trinity P2 Pharmaceutical Counterion Analysis Columns, Thermo Scientific

Acclaim™ Trinity P2 Pharmaceutical Counterion Analysis Columns, Thermo Scientific

Supplier: Thermo Scientific

The Thermo Scientific™ Acclaim™ Trinity™ P2 column is a high-performance, silica-based column specifically designed for separation of pharmaceutical mono- and multi-valent counterions by high-performance liquid chromatography (HPLC). This column was engineered for analytical chemists who need simple, robust, fast, generic methods. The Acclaim Trinity P2 columns provide an effective solution for counterion analysis using one column and one method on a standard HPLC instrument.

Expand 6 Items
Loading...

ICP-MS Analytes B4, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.

The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.

US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:

• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements

CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

Expand 1 Items
Loading...

ICP Interferents A1, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.

The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.

US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:

• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements

CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (INT-A1) and Solution AB, a combination of interferents (INT-A1) and analytes (INT-B3). Solution A is prepared by diluting INT-A1 20-fold. Solution AB is prepared by diluting INT-A1 20-fold and INT-B3 100-fold; for example, 5 ml of INT-A1 and 1 ml of INT-B3 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

CLP ILM 02.0 Standards for ICP
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (INT-A1) and Solution AB, a combination of interferents (INT-A1) and analytes (INT-B1). Solution A is prepared by diluting INT-A1 20-fold. Solution AB is prepared by diluting INT-A1 20-fold and INT-B1 100-fold; for example, 5 ml of INT-A1 and 1 ml of INT-B1 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

Expand 1 Items
Loading...

N-Methyl-2-pyrrolidone (NMP) ≥99% ACS

Supplier: Spectrum Chemical Mfg. Corp.

1-Methyl-2-pyrrolidone, Reagent, ACS is a laboratory analytical reagent that is miscible with water and several other solvents, including ethyl acetate, chloroform, benzene and alcohols and ketones. 1-METHYL-2-PYRROLIDINONE, REAGENT, ACS is colorless to slightly yellow, and is used in the processing of petrochemicals to recover pure hydrocarbons. It is also commonly used to dissolve a broad range of chemicals, in particular polymers. There are several industrial uses, including treating surfaces of textiles, resins and plastics, as well as for stripping paint. As an ACS grade Reagent, Spectrum Chemical manufactured 1-Methyl-2-pyrrolidinone is used as the quality standard against which other substances are graded and has met the toughest regulatory standards for quality and pureness

Expand 1 Items
Loading...

Performance Check Solution for US EPA Method 508, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Pesticides, PCBs and Herbicides

The EPA is tasked with the monitoring of environmental systems as they pertain to contamination and human health. The methods issued by the EPA are created to respond to specific toxins or persistent organic pollutants (POPs) found in environmental samples such as soil, source water, drinking water, and waste. In particular, pollutants such as polychlorinated biphenyls (PCBs), which were in widespread industrial use up until their restriction, are of concern due to their stable and persistent nature in the environment. Another group of chemicals of high concern is the hundreds of commercial pesticides and herbicides in use in the world today. Pesticides, from algaecides to virucides, are used in large quantities in industrial and private agriculture. The concern over human pesticide exposure over the past few decades has led to extensive monitoring of these pesticides. It has been reported that over 98% of insecticides and 95% of herbicides affect areas other than their intended target product. It is essential that monitoring agencies have accurate standard mixes to measure the pesticide levels in the environment.

Many new pesticides are now being tested using highly sensitive LC/MS techniques, in addition to traditional GC techniques, to determine minute amounts of residue in environmental samples and food products.

At SPEX CertiPrep, we facilitate ease of monitoring and testing of pesticides by creating pesticide test mixes to suit your monitoring needs. SPEX CertiPrep is the leader in offering pesticide standards designed to work within EPA, AOAC and FDA analytical testing methods using all of the leading analytical techniques: LC, LC/MS, GC, and GC/MS. Many pesticide standard mixes are readily available in our catalog along with a large list of single pesticide standards. In addition, custom pesticide mixes can be made to your specifications to create a mix that meets your needs.

US EPA Method 508 is an analytical method for the monitoring of organochlorine pesticides and PCBs in drinking water and ground water by GC/ECD

Expand 1 Items
Loading...

Method 531 Analyte Mix A, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Pesticides, PCBs and Herbicides

The EPA is tasked with the monitoring of environmental systems as they pertain to contamination and human health. The methods issued by the EPA are created to respond to specific toxins or persistent organic pollutants (POPs) found in environmental samples such as soil, source water, drinking water, and waste. In particular, pollutants such as polychlorinated biphenyls (PCBs), which were in widespread industrial use up until their restriction, are of concern due to their stable and persistent nature in the environment. Another group of chemicals of high concern is the hundreds of commercial pesticides and herbicides in use in the world today. Pesticides, from algaecides to virucides, are used in large quantities in industrial and private agriculture. The concern over human pesticide exposure over the past few decades has led to extensive monitoring of these pesticides. It has been reported that over 98% of insecticides and 95% of herbicides affect areas other than their intended target product. It is essential that monitoring agencies have accurate standard mixes to measure the pesticide levels in the environment.

Many new pesticides are now being tested using highly sensitive LC/MS techniques, in addition to traditional GC techniques, to determine minute amounts of residue in environmental samples and food products.

At SPEX CertiPrep, we facilitate ease of monitoring and testing of pesticides by creating pesticide test mixes to suit your monitoring needs. SPEX CertiPrep is the leader in offering pesticide standards designed to work within EPA, AOAC and FDA analytical testing methods using all of the leading analytical techniques: LC, LC/MS, GC, and GC/MS. Many pesticide standard mixes are readily available in our catalog along with a large list of single pesticide standards. In addition, custom pesticide mixes can be made to your specifications to create a mix that meets your needs.

US EPA Method 531 is an analytical method for the monitoring of n-methylcarbamoyloximes and n-methylcarbamates in drinking water and ground water by HPLC and a fluorescence detector

Expand 1 Items
Loading...

Initial Combination Calibration Standard for US EPA Method 8082 and CLP Series Methods, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Pesticides, PCBs and Herbicides

The EPA is tasked with the monitoring of environmental systems as they pertain to contamination and human health. The methods issued by the EPA are created to respond to specific toxins or persistent organic pollutants (POPs) found in environmental samples such as soil, source water, drinking water, and waste. In particular, pollutants such as polychlorinated biphenyls (PCBs), which were in widespread industrial use up until their restriction, are of concern due to their stable and persistent nature in the environment. Another group of chemicals of high concern is the hundreds of commercial pesticides and herbicides in use in the world today. Pesticides, from algaecides to virucides, are used in large quantities in industrial and private agriculture. The concern over human pesticide exposure over the past few decades has led to extensive monitoring of these pesticides. It has been reported that over 98% of insecticides and 95% of herbicides affect areas other than their intended target product. It is essential that monitoring agencies have accurate standard mixes to measure the pesticide levels in the environment.

Many new pesticides are now being tested using highly sensitive LC/MS techniques, in addition to traditional GC techniques, to determine minute amounts of residue in environmental samples and food products.

At SPEX CertiPrep, we facilitate ease of monitoring and testing of pesticides by creating pesticide test mixes to suit your monitoring needs. SPEX CertiPrep is the leader in offering pesticide standards designed to work within EPA, AOAC and FDA analytical testing methods using all of the leading analytical techniques: LC, LC/MS, GC, and GC/MS. Many pesticide standard mixes are readily available in our catalog along with a large list of single pesticide standards. In addition, custom pesticide mixes can be made to your specifications to create a mix that meets your needs.

US EPA Method 8082 is an analytical method for the monitoring of PCBs in environmental samples by GC/ECD or GC/ELCD

Expand 1 Items
Loading...

Copper(II) sulfate, anhydrous ≥98%, powder, Reagent Grade

Supplier: Spectrum Chemical Mfg. Corp.

Cupric Sulfate, Anhydrous, Powder, Reagent also known as Copper(II) Sulfate is an inorganic pale green or gray-white powder. As an analytical reagent it is used in Benedict's solution and Fehling's solution to test for reducing sugars and in Biuret reagent to test for proteins. The Reagent grade denotes that this chemical is the highest quality commercially available and that the American Chemical Society has not officially set any specifications for this material. Spectrum Chemical manufactured Reagent grade products meet the toughest regulatory standards for quality and purity.

Expand 1 Items
Loading...
SureSTART™ Glass Screw Top Vials, 2 ml, Level 2 High-Throughput Applications, Thermo Scientific

SureSTART™ Glass Screw Top Vials, 2 ml, Level 2 High-Throughput Applications, Thermo Scientific

Supplier: Thermo Scientific

Choose Thermo Scientific™ SureSTART™ 2 ml glass screw top vials, performance level 2, to ensure high quality data with an uninterrupted workflow in high-throughput applications using GC, HPLC/UHPLC, and single or triple quadrupole MS systems. Use level 2 vials for routine QA/QC applications, where the analyte levels are achievable or close to the method detection level. Available in clear and amber glass, these 2 ml screw top vials have very low metal content, extractables, and leachables and conform to high standards so that you can to meet your regulatory requirements. They are specification certified to ensure their physical dimensions and autosampler compatibility.

Expand 7 Items
Loading...

Poly(vinylidene fluoride)

Supplier: Thermo Scientific Chemicals

Poly(vinylidene fluoride) is useful in coatings, film, filter cloth, instrument linings, filtration membranes, pump parts, linings and valves. It is also employed as a material for transducers in devices such as headphones, microphones and sonic detectors. It is also essential for piezoelectric and electrostrictive applications. In addition, it is useful for monofilament fishing lines replacing nylon monofilament. It acts as a standard binder used in the production of composite electrodes for lithium ion batteries. It serves as a high grade insulator for wires, nanomaterials and pressure sensors. It is utilized to make filters which are used to prepare samples for high performance liquid chromatography and other advanced analytical techniques.
Notes: Incompatible with strong oxidizing agents.

Expand 3 Items
Loading...
GsBP®-InoWax Polar, PEG GC Columns, GS-Tek

GsBP®-InoWax Polar, PEG GC Columns, GS-Tek

Supplier: General Separation Technologies, Inc.

Typical application: Alcohols II and III, Amines (low MW), Amines/ Alcohols/ Chlorides, Aromatics analysis: ASTM D16 analytes, Aromatics II, Blood alcohol, Bourbon, Branched alcohols, BTEX, Chlorinated Isooctane, Citronella java oil, Esters III, Ethylene oxide, FAME Standard I, FAMEs (Coca Butter), Fast styrene analysis, Flavor volatiles, Formaldehyde Underivatized, Fragrance allergens, Fragrance Reference Standard II, Free Fatty Acids, Free Organic Acids/C4-C5 Isomers, Impurities in Ethylbenzene, Impurities in mixed xylenes, Impurities in p-Xylene-ASTM D3798, Impurities in styrene, Industrial Solvent, Lavender Oil Spiked with Camphor, Monomers in latex paint by headspace, Mushroom aroma (Synthetic), Nitrosamines, Nutmeg oil, Organic acids, Phenols III, Polyunsaturated fatty acid methyl esters, Rapeseed oil, Rapid analysis of water in organic solvents, Solvents I, II, Spearmint oil, Strawberry syrup, Sulphur and Selenium in Garlic by Headspace, Tramanian lavander oil, Volatile organics, Volatile sulfurs.

Expand 42 Items
Loading...
GsBP®-InoWax-MS Polar, PEG GC Columns, GS-Tek

GsBP®-InoWax-MS Polar, PEG GC Columns, GS-Tek

Supplier: General Separation Technologies, Inc.

Typical Application: Alcohols II and III, Amines (low MW), Amines/ Alcohols/ Chlorides, Aromatics Analysis: ASTM D16 Analytes, Aromatics II, Blood Alcohol, Bourbon, Branched alcohols, BTEX, Chlorinated Isooctane, Citronella Java Oil, Esters III, Ethylene Oxide, FAME Standard I, FAMEs (Coca Butter), Fast Styrene Analysis, Flavor Volatiles, Formaldehyde Underivatized, Fragrance Allergens, Fragrance Reference Standard II, Free Fatty Acids, Free Organic Acids/C4-C5 Isomers, Impurities in Ethylbenzene, Impurities in Mixed Xylenes, Impurities in p-Xylene-ASTM D3798, Impurities in Styrene, Industrial Solvent, Lavender Oil Spiked with Camphor, Monomers in Latex Paint by Headspace, Mushroom Aroma (Synthetic), Nitrosamines, Nutmeg Oil, Organic Acids, Phenols III, Polyunsaturated Fatty Acid Methyl Esters, Rapeseed Oil, Rapid Analysis of Water in Organic Solvents, Solvents I, II, Spearmint Oil, Strawberry Syrup, Sulfur and Selenium in Garlic by Headspace, Tramanian Lavander Oil, Volatile Organics, Volatile Sulphurs.

Expand 5 Items
Loading...
Ion Chromatography (IC) Anion and Cation Check Standards, VWR Chemicals BDH®

Ion Chromatography (IC) Anion and Cation Check Standards, VWR Chemicals BDH®

Supplier: VWR International

Ion chromatography (IC) is an analytical process for the separation of ions based on charge affinity. IC can be used for a variety of different kinds of charged analytes from single elements to large proteins.

Expand 6 Items
Loading...
VWR® Certified Reference Materials, Oxide

VWR® Certified Reference Materials, Oxide

Supplier: KLEN INTERNATIONAL (74) PTY LTD.

KLEN's CRMs are certified products containing a range of analytes including Au, Ag, Pt, and Pd at various ppm levels

Expand 1 Items
Loading...
Environmental Wastewater Certified Reference Materials

Environmental Wastewater Certified Reference Materials

Supplier: SPEX CERTIPREP LLC

Validate analytical methods and evaluate the quality of your results with certified reference materials.

Expand 4 Items
Loading...
Hydrochloric acid (0.027 -  0.27 mol/l; 0.027 -  0.27 N) 0.10 N analytical reagent, VWR Chemicals BDH®

Hydrochloric acid (0.027 - 0.27 mol/l; 0.027 - 0.27 N) 0.10 N analytical reagent, VWR Chemicals BDH®

Supplier: VWR International

Meets AOAC 936.15 standard and ASTM E200-91 standard. Made with high purity acid and deionized water. Suitable as a titrant.

Expand 3 Items
Loading...
Sodium hydroxide (0.55 -  1.3 mol/l; 0.55 -  1.3 N) in aqueous solution 1.0 N in aqueous solution analytical reagent, VWR Chemicals BDH®
Expand 3 Items
Loading...
Potassium hydroxide (0.35 -  1 mol/l;  0.35 -  1 N) in methanol 0.5 N in methanol analytical reagent, VWR Chemicals BDH®

Potassium hydroxide (0.35 - 1 mol/l; 0.35 - 1 N) in methanol 0.5 N in methanol analytical reagent, VWR Chemicals BDH®

Supplier: VWR International

Standardized at 25 °C against chemicals whose certification is traceable to NIST.

Expand 1 Items
Loading...
Volatile Organics Combination Analyte Mix

Volatile Organics Combination Analyte Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 624 is a general analytical method for the monitoring of VOCs in municipal and industrial wastewater by GC/MS.

Expand 1 Items
Loading...
HICAL Acids Mix

HICAL Acids Mix

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
Loading...
Phenols Mix

Phenols Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
Loading...
Purgeable Gases Mix B

Purgeable Gases Mix B

Supplier: SPEX CERTIPREP LLC

US EPA method 624 is a general analytical method for the monitoring of VOCs in municipal and industrial wastewater by GC/MS.

Expand 1 Items
Loading...
Potassium pyroantimonate USP Test Solution (TS) 1 analytical reagent, VWR Chemicals BDH®

Potassium pyroantimonate USP Test Solution (TS) 1 analytical reagent, VWR Chemicals BDH®

Supplier: VWR International

Potassium pyroantimonate USP Test Solution (TS) 1 analytical reagent, VWR Chemicals BDH®

Expand 1 Items
Loading...
Balance Mix, Option A

Balance Mix, Option A

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS. CLP series methods: The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods and SW-846. The CLP volatile organic analysis method is an analytical method for the analysis of aqueous or solid samples for VOCs by GC/MS.

Expand 1 Items
Loading...
Sulfuric acid ( 0.51 mol/l) in aqueous solution 0.1 N in aqueous solution analytical reagent, VWR Chemicals BDH®

Sulfuric acid ( 0.51 mol/l) in aqueous solution 0.1 N in aqueous solution analytical reagent, VWR Chemicals BDH®

Supplier: VWR International

Meets ASTM E200-91 and AOAC 890-01 standards. Made with high purity acid and deionized water. Suitable as a titrant.

Expand 3 Items
Loading...
Antifoam Agent for Purge-and-Trap Samples, Restek

Antifoam Agent for Purge-and-Trap Samples, Restek

Supplier: Restek

Foam generated as purge gas passes through a sample can enter the analytical trap and possibly the GC column. This silica-containing antifoam agent is effective over a wide pH range and will not conflict with chromatography of target analytes.

Expand 1 Items
Loading...
Acrolein and Acrylonitrile Standards

Acrolein and Acrylonitrile Standards

Supplier: SPEX CERTIPREP LLC

US EPA method 603 is a general analytical method for the separation of acrolein and acrylonitrile in municipal and industrial wastewater by GC/FID.

Expand 1 Items
Loading...
Base Neutral and Acid Combination Calibration Standard

Base Neutral and Acid Combination Calibration Standard

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS. US EPA method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS. CLP series methods: The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods and SW-846. The CLP volatile organic analysis method is an analytical method for the analysis of aqueous or solid samples for VOCs by GC/MS.

Expand 1 Items
Loading...
Sort By
Recommended for You