You searched for: Standards
Meeting regulations in any industry, standards are essential for periodically checking the accuracy of equipment pieces. By comparing against the known values, output readings detect errors present and inform personnel adjustments are required. Once the settings of the manual or automatic instruments have returned to zero, the reestablished conditions will yield optimal working performance. Calibrating with concentrated standards eliminates the possibility that environmental changes will induce instrumental miscalculation when accuracy matters most.
EPA method 501 Trihalomethane Mixture, Restek
Supplier: Restek
Mixture is packaged in purge and trap methanol at a concentration of 200 µg/mL in a 1 ml ampoule.
Expand 1 Items
611 Haloethers Calibration Mix (5 components), Restek
Supplier: Restek
Haloethers calibration mix contains bis(2-chloroethoxy)methane, bis(2-chloroethyl)ether, 4-bromophenyl phenyl ether, 4-chlorophenyl phenyl ether, 2,2'-oxybis(1-chloropropane).
Expand 1 Items
PVOC Mix (California) (7 Components), Restek
Supplier: Restek
Mix contains: Benzene (71-43-2); Ethylbenzene (100-41-4); Methyl tert-butyl ether (MTBE) (1634-04-4); Toluene (108-88-3); m-Xylene (108-38-3); o-Xylene (95-47-6); p-Xylene (106-42-3).
Expand 1 Items
EPA Methods 502.1, 502.2, 524.2, 601, 624, 8010, 8021, 8240 and 8260 Gas Mixture, NSI
Supplier: SPEX CERTIPREP LLC
Mixture is packaged in methanol at a concentration of 1000µg/mL in a 1.5mL ampule.
Expand 1 Items
502.2 Calibration Mix #1 (gases) (6 components), Restek
Supplier: Restek
Contains: Bromomethane (methyl bromide) (74-83-9); Chloroethane (ethyl chloride) (75-00-3); Chloromethane (methyl chloride) (74-87-3); Dichlorodifluoromethane (CFC-12) (75-71-8); Trichlorofluoromethane (CFC-11) (75-69-4); Vinyl chloride (75-01-4)
Expand 1 Items
Aroclor 1248 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Semivolatiles
US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.
US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.
Expand 1 Items
Aroclor 1242 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Semivolatiles
US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.
US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.
Expand 1 Items
ICP-MS Interferents B3 with Mercury, 2 µg/ml (2 ppm), SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.
Expand 1 Items
8260 Acetate Mix (5 components), Restek
Supplier: Restek
This contains: n-butyl acetate; ethyl acetate; isopropyl acetate; n-propyl acetate; vinyl acetate.
Expand 1 Items
LaMotte® Soil Micronutrients Outfit
Supplier: LaMotte
Tests for Nine Essential Minor Elements
Expand 2 Items
Environmental Drinking Water Inorganics Proficiency Tests
Supplier: SPEX CERTIPREP LLC
Ensure state and accreditation regulation compliance with proficiency testing.
Expand 8 Items
EPA Method 501 Trihalomethane Mixture, Ultra Scientific
Supplier: Ultra Scientific
Mixture is packaged in methyl alcohol in 1 mL ampules.
Expand 1 Items
Inorganic Disinfection By-Products QC Concentrate, Certified Reference Material
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
PCBs QC Concentrate
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
EPA method 418.1 TPH Calibration Mixture, Restek
Supplier: Restek
For the infrared spectrophotometric method for the determination of Total Recoverable Petroleum Hydrocarbons.
Expand 1 Items
MBAs QC Concentrate
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
Simple Nutrients QC Concentrate, Certified Reference Material
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
Residue QC Concentrate, Certified Reference Material
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
Silica Drinking Water QC Concentrate, Certified Reference Material
Supplier: SPEX CERTIPREP LLC
Meet or exceed performance criteria with QC samples.
Expand 1 Items
8240 Alcohols Mix (5 components), Restek
Supplier: Restek
Mix contains: Allyl alcohol (2-propen-1-ol) (107-18-6); 2-Chloroethanol (107-07-3); Ethanol (64-17-5); Isobutyl alcohol (78-83-1); Propargyl alcohol (107-19-7).
Expand 1 Items
8240 Nitriles Mix (7 components), Restek
Supplier: Restek
Mix contains: Acrylonitrile (107-13-1); Ethyl methacrylate (97-63-2); Malononitrile (109-77-3); Methacrylonitrile (126-98-7); Methyl methacrylate (80-62-6); Propionitrile (107-12-0); Styrene (100-42-5).
Expand 1 Items
Organic Reference Standards, Endotoxin, USP
Supplier: USP
(11,000 USP Endotoxin Units) (COLD SHIPMENT REQUIRED)
Expand 1 Items
Organic Reference Standard, Ergocalciferol, USP
Supplier: USP
(30 mg/ampule; 5 ampules) (Vitamin D2)
Expand 1 Items
High Concentration Acid Surrogates for CLP Series Methods
Supplier: SPEX CERTIPREP LLC
CLP Series Methods: The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods and SW-846. The CLP Volatile Organic Analysis Method is an analytical method for the analysis of aqueous or solid samples for VOCs by GC/MS.
Expand 1 Items
Fuel Oil Degradation Mix (4 components), Restek
Supplier: Restek
Subsurface degradation of fuel oil spills can be estimated by examining the ratios of C17/pristane and C18/phytane. To assist in identifying these four compounds from the complex fuel oil analysis, Restek offer a product that contains these compounds for retention time determination.
Expand 1 Items
Volatiles Mix D for CLP SOW 2/88 and 3/90 (High Level)
Supplier: SPEX CERTIPREP LLC
Volatiles, CLP Series Methods: The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods and SW-846. The CLP Volatile Organic Analysis Method is an analytical method for the analysis of aqueous or solid samples for VOCs by GC/MS.
Expand 1 Items
Sulphate Standard Solution
Supplier: Hach
Standard solution for accuracy checks in sulfate determinations.
Expand 1 Items
EPA method 505 Organohalide Pesticide Mixture, Restek
Supplier: Restek
Mixture is packaged in methanol at a concentration of 200 µg/mL in a 1 mL ampoule.
Expand 1 Items
2-Chloroethanol, Restek
Supplier: Restek
2000ug/mL. Solvent: Purge and Trap Grade Methanol. Packaged 1mL/ampule.